f(mm) F# Sensor T @8~12μm FOV(°) Focus M.B.F.L
(mm)
Mount Dimensions (mm) Operation Temperature(℃) Sealing Front Lens Coating Application
7.5 1.2 336*256 17μm >88% 25.2(H)×18.9(V) Athermalized 9.7 M24×0.5 L19;Ф25.12 – 40℃ to +80℃ IP 67 DLC Security
7 1 384*288 17μm >94% 55.3(H)×40.7(V) Athermalized 8.5 M25×0.5 L18.5;Ф28.5 – 40℃ to +80℃ IP 54 AR Automobile
9.7 1 384*288 17μm >94% 37.5(H)×28.5(V) Athermalized 7.5 M22×0.5 L13.1;Ф23 – 40℃ to +80℃ IP54 AR Automobile
13 1 384*288 17μm >96% 28.4(H)×21.4(V) Athermalized 9 M25×0.5 L18;Ф28.5 – 40℃ to +80℃ IP54 AR Automobile
15 1 384*288 17μm >85% 24.2(H)×18.4(V) Athermalized 7.75 M45×1 L25;Ф45 – 40℃ to +80℃ IP 67 DLC Security
35 1.2 384*288 17μm >83% 10.6(H)×8.0(V) Athermalized 9 M33×0.75 L32;Ф37 – 40℃ to +80℃ IP 67 AR Security
60 1 384*288 17μm >87% 6.2(H)×4.6(V) Athermalized 8.9 M37×0.75 L71.4;Ф69 – 40℃ to +80℃ IP 54 DLC Security
5.8 1 640*480 17μm >85% 92.4(H)×73.5(V) Athermalized 9 M46×0.75 L49.5;Ф59 – 40℃ to +80℃ IP 67 DLC Security
9 1 640*480 17μm >85% 72.8(H)×53.4(V) Athermalized 4.5 M25×0.5 L32.7;Ф33 – 40℃ to +80℃ IP 54 AR Security
9 1.2 640*480 17μm >85% 73(H)×57.4(V) Athermalized 9.7 M24×0.5 L21.4;Ф25.12 – 40℃ to +80℃ IP67 DLC Security
13 1 640*480 17μm >85% 48.6(H)×36.4(V) Athermalized 4.5 M25×0.5 L31.5;Ф29 – 40℃ to +80℃ IP 54 AR Security
15 1 640*480 17μm >85% 42.5(H)×33.3(V) Athermalized 7.75 M45×1 L34.7;Ф45 – 40℃ to +80℃ IP 67 DLC Security
19 1 640*480 17μm >91% 28.4(H)×21.5(V) Athermalized 8 M34×0.5 L24;Ф38 – 40℃ to +80℃ IP 67 AR Security
25 1 640*480 17μm >88% 24.6(H)×18.5(V) Athermalized 9.7 M34×0.5 L30;Ф34.9 – 40℃ to +80℃ IP 67 DLC Security
35 1 640*512 17μm >85% 17.2(H)×13.8(V) Athermalized 7.75 M45×1 L45.5;Ф47 – 40℃ to +80℃ IP 67 DLC Security
50 1 640*480 17μm >91% 12.4(H)×9.3(V) Athermalized 9 M45×1 L52;Ф66 – 40℃ to +80℃ IP 67 AR Security
50 1 640*480 17μm >85% 12.4(H)×9.3(V) Athermalized 9.5 M34×0.5 L66;Ф58.4 – 40℃ to +80℃ IP 67 DLC Security
50 1.2 640*480 17μm >88% 12.4(H)×9.6(V) Athermalized 9.5 M34×0.5 L63.1;Ф58.4 – 40℃ to +80℃ IP 67 DLC Security
60 1 640*480 17μm >91% 10.4(H)×7.8(V) Athermalized 9.6 M34×0.75 L68.5;Ф71 – 40℃ to +80℃ IP 67 AR Security
60 1.2 640*480 17μm >85% 10.3(H)×7.8(V) Athermalized 9.5 M34×0.5 L65;Ф61.4 – 40℃ to +80℃ IP 67 DLC Security
75 1 640*512 17μm >85% 8.5(H)×6.4(V) Athermalized 8.75 flange L93.7;Ф115 – 40℃ to +80℃ IP 67 F.L.O DLC Security
100 1.4 640*512 17μm >85% 6.2(H)×5.0(V) Athermalized 9.5 M34×0.5 L106.5;Ф89 – 40℃ to +80℃ IP 67 DLC Security
100 1 640*480 17μm >91% 6.4(H)×4.8(V) Athermalized 8 M34×0.5 L114;Ф110 – 40℃ to +80℃ IP 67 AR Security
25 1 640*480 17μm >85% 24.7(H)×18.6 (V) Motorized 9.5 M34×0.5 L50.1;Ф50 – 40℃ to +80℃ IP 54 DLC Security
35 1 640*480 17μm >91% 17.6(H)×13.3(V) Motorized 9.5 M34x0.5 L58.4;Ф50 – 40℃ to +60℃ IP54 AR Security
50 1 640*480 17μm >90% 12.4(H)×9.3(V) Motorized 9.5 M34×0.5 L77.5;Ф92 – 40℃ to +60℃ IP 67 F.L.O DLC Security
75 1 640*512 17μm >88% 8.3(H)×6.6 (V) Motorized 9 M45×1 L102;Ф109 – 40℃ to +60℃ IP 67 F.L.O AR Security
100 1 640*512 17μm >88% 6.2(H)×5.0 (V) Motorized 12 flange L139;Ф137 – 40℃ to +60℃ IP54 DLC Security
100 1.2 640*512 17μm >88% 6.2(H)×5.0 (V) Motorized 12 flange L122;Ф117 – 40℃ to +60℃ IP 67 DLC Security
130 1.2 640*512 17μm >94% 4.8(H)×3.8(V) Motorized 9.7 M34×0.5 L117.9;Ф118 – 40℃ to +60℃ IP54 AR Security
150 1.2 640*480 17μm >87% 4.1(H)×3.1(V) Motorized 13.6 flange L197.9;Ф166 – 40℃ to +60℃ IP 67 DLC Security
150 1 640*480 17μm >88% 4.1(H)×3.1(V) Motorized 8.5 M45×1 L210.5;Ф180 – 40℃ to +60℃ IP54 DLC Security
f25- f75 1 640*512 17μm >85% f25=25.7(H)×20.3(V)
f75=8.3(H)×6.6(V)
Motorized Continuous Zoom 12 flange L128.2;Ф137 – 40℃ to +60℃ IP 67 F.L.O AR Security
f20- f100 1 640*512 17μm >80% f20=32.5(H)×25.6(V)
f100=6.2(H)×5.0(V)
Motorized Continuous Zoom 12 flange L170;Ф187 – 40℃ to +60℃ IP 67 F.L.O DLC Security
f37.5-f150 1.2 640*480 17μm >83% f37.5=16.9(H)×12.6(V)
f150=4.2(H)×3.1(V)
Motorized Continuous Zoom 15 flange L205.5;Ф165.5 – 40℃ to +60℃ IP 67 F.L.O DLC Security
f45-f180 1.2 640*512 17μm >80% f45=13.8(H)x11.1(V)
f180=3.5(H)x2.8(V)
Motorized Continuous Zoom 9.25 M45×1 L262.9;Ф195 – 40℃ to +60℃ IP 67 F.L.O DLC Security
3.7 1 384*288 17μm >88% 90.8(H)×71(V) ∞~0.3m 10.95 M32×0.75 L47.1;Ф62 – 40℃ to +80℃ IP54 AR thermometry
6.5 1 384*288 17μm >91% 56.6(H)×42.8(V) ∞~0.1m 8 M34×0.75 L28;Ф36 – 40℃ to +80℃ IP54 AR thermometry
8 1 384*288 17μm >91% 47(H)×35(V) ∞~0.5m 9.5 M38x1 L35;Ф45 – 40℃ to +80℃ IP54 AR thermometry
10 1 384*288 17μm >91% 36.2(H)×27.4(V) ∞~0.1m 8 M34x0.75 L35;Ф42 – 40℃ to +80℃ IP54 AR thermometry
13 1 384*288 17μm >91% 29.6(H)×21.9(V) ∞~0.5m 10.95 M32×0.75 L33.5;Ф50 – 40℃ to +80℃ IP 54 AR thermometry
15 1 384*288 17μm >91% 25.4(H)×18.8(V) ∞~0.5m 10.5 M29×0.75 L33;Ф40 – 40℃ to +80℃ IP 67 AR thermometry
25 1 384*288 17μm >79% 15(H)×11.2(V) ∞~2m 10.95 M32×0.75 L33.5;Ф50 – 40℃ to +80℃ IP 54 AR thermometry
10 1 640*480 17μm >87% 66.2(H)×48.2(V) ∞~0.5m 10.5 M34×0.75 L40;Ф32 – 40℃ to +60℃ IP 67 DLC thermometry
14 1 640*480 17μm >87% 45(H)×33.8(V) ∞~0.5m 7.3 flange L51.4;Ф51 – 40℃ to +80℃ IP 54 DLC thermometry
25 1 640*480 17μm >60% 24.7(H)×18.6(V) ∞~0.5m 8.5 M37×0.75 L39.2;Ф49.5 – 40℃ to +80℃ IP54 AR thermometry
60 1 640*480 17μm >87% 10.4(H)×7.8(V) ∞~6m 10 M34×0.75 L76.9;Ф72 – 40℃ to +60℃ IP 67 DLC Security
75 1 640*480 17μm >87% 8.2(H)×6.2(V) ∞~7m 9.5 M34×0.75 L100.4;Ф87 – 40℃ to +60℃ IP 67 DLC Security
100 1 640*480 17μm >87% 6.2(H)×4.6(V) ∞~10m 9 M46×0.75 L163.6;Ф110 – 40℃ to +60℃ IP 67 DLC Security
150 1 640*480 17μm >87% 4.1(H)×3.1(V) ∞~40m 9 M46×0.75 L206.2;Ф161 – 40℃ to +60℃ IP 67 DLC Security
200 1.4 640*480 17μm >87% 3.1(H)×2.3(V) ∞~20m 9 M46×0.75 L245;Ф153 – 40℃ to +60℃ IP 67 DLC Security
1.85 1.35 80*80 34μm >97% 90(H)×90(V) / 2.5 M10×0.5 L3.2;Ф10 – 40℃ to +80℃ IP 54 AR thermometry
2.2 1.2 80*80 34μm >97% 69.8(H)×69.8(V) / 3 M12×0.5 L5.2;Ф12 – 40℃ to +80℃ IP 67 AR thermometry
6.5 1 80*60 35μm >97% 25(H)×18.7(V) / 5.5 M16×0.5 L12.5;Ф19.5 – 40℃ to +80℃ IP 54 AR thermometry
Remark
1.T: Transmission; L: Length;M.B.F.L: Mechanical Back Focal Length; F.L.O: Front Lens Only
2.The mechanism parameter showed is standard,we still have other different mechanism parameter for your choice or design specially
3. P/N with “*” would be updated on off-the-shelf lens with no label.The P/N is to be decided.